Klixon 5TC Series
 
 
Aircraft Circuit Breakers
 
    ACB Catalog



Klixon
klixon@sensata.com
Phone: 1-508-236-3287
Fax: 1-508-236-1598
more »
Part numbers
Don’t risk ordering the wrong part. Contact us or a distributor.



About these pages
Sensata Technologies is in the process of updating our web pages. Please bear with us during this process. If you have questions or comments, we’d like to hear from you. Please see contact us.



Voltage Drop /\ Top
Amp Rating
Max. Voltage Drop*
20
0.15
25
0.15
35
0.15
50
0.15
* Maximum voltage drop at nominal rated current.

Site Updated February 16, 2018

* * * Sensata > Products > Klixon Brand > Circuit Breakers > Aircraft >

Klixon® 5TC series
20 to 50 amp, single–phase, ambient compensated



Features and Overview Performance Characteristics
Voltage Drop Qualifications
Calibration Chart Spec Sheet PDFs
Part Numbering  
Ask a question » Contacts and distributors »




Features and Overview /\ Top

Miniature size
Light weight
Single–phase
Ambient compensated
Trip–free design
Current rating: 20 to 50 amps
Coordinated ratings
 
High vibration resistance
High interrupting capacity
Options include: standard or auxiliary switch configuration, terminal barriers
Typical use: Aircraft, avionics and electronic systems


Klixon single–phase TC devices are the smallest, lightest, high performance aircraft circuit breakers available today. They represent the state-of-the-art protection of today’s aerospace power systems. Their light weight and small size make them especially well suited for aircraft, avionics and electronic systems.

The Klixon trademark has set the standard for aerospace circuit breakers. For a small, light weight configuration, the TC series offers the endurance and reliability required by exacting military specifications, and are available in standard current ratings from 1 through 50 amperes.
* * *



Klixon
Aircraft Circuit Breakers
Aircraft Circuit Breakers
Coordination
The single–phase 5TC breaker rating is coordinated so that in the event of a fault of up to 600 amps let–through current any rating will trip before another circuit breaker twice its rating. This results in improved overall equipment performance since only the smallest faulted circuit is interrupted, while larger circuits remain operational.

Ambient Temperature Compensation
The 5TC serves as an ambient compensated circuit breaker permits system designers to specify smaller gauge wire where the circuit breaker and wiring are exposed to different ambient temperatures.

They are especially suited for application where ambient temperature exceeds the 160°F (71°C) maximum of non–ambient compensated thermal circuit breakers. The 5TC series may be applied where operating temperatures are as high as 250°F (121°C), with no derating of the circuit breaker. This eliminates the need for cooling air and allows substantial weight, space and cost savings.

Trip–Free
The complete line of TC series circuit breakers is trip–free. The circuit breaker cannot be maintained closed during an overload even with the actuator button held closed.



Performance Characteristics /\ Top
Vibration
10G minimum, 80–500 Hz (other vibration levels available)
Mechanical Shock
50G
Acceleration
10G
Weight
Standard device: 53 grams (no hardware), 58 grams (hardware)
Auxiliary device: 55 grams (no hardware), 59 grams (hardware)
Interrupt Current
20–50 amps: 4000 amps at 28 VDC
20–50 amps: 2000 amps at 115 VAC, 400 Hz
Endurance
2,500 cycles: 115 VAC, 400 Hz inductive
2,500 cycles: 28 VDC inductive
2,500 cycles: 28 VDC resistive
5,000 cycles: Mechanical, no load


Qualifications /\ Top
ASNE
ASNE0732-005 (our 5TC65 auxiliary device)
NSA
NSA93121 (our 5TC50 standard device)
To view qualifications on all Klixon aircraft circuit breakers, see the cross reference chart.


Calibration Chart For a Standard Device /\ Top
Temp.
Minimum Ultimate Trip
Maximum Ultimate Trip
Trip Time in seconds
200%
500%
1000%
23°C
110%
145%
2–18
0.15–2.5
0.045–0.6
-54°C
110%
165%
70 seconds max.
0.15–2.5
0.045–0.6
70°C
105%
145%
1.5 seconds min.
0.15–2.5
0.045–0.6
125°C
90%
145%
1.5 seconds min.
0.15–2.5
0.045–0.6
The most typical device is 20–50 amps. For others, please contact us.


Part Numbering /\ Top
5TCX-Y
Where 5TC is the basic part number, X depicts the style, and –Y designates the applicable amperage rating. For more detailed information, please see spec sheets below.


Spec Sheets For Our Most Popular Devices /\ Top
Specification sheets contain detailed drawings, amp ratings, characteristics, and more...
5TCX
Device Type
Spec Sheet
Coming soon!