Using a bimetal, snap acting disc as the sensing and actuating element, the large frame P series thermal circuit breaker
provides trouble-free over-current protection for harsh environments.
Available in two configurations:
PDLA: Automatic reset
PDLM: Manual reset
Applications
Military vehicles and equipment where precise ultimate trip characteristics are required
Trip Curve
Approximate Time — Current Characteristics at 77°F (25°C)
Derating Curve
Approximate Effect of Ambient Temperature on Ultimate Trip
Performance characteristics are based on room temperature (77°F). Consult derating curve at left for ambient temperatures
significantly higher or lower than standard room temperature.
Example: At 77°F the device is calibrated to hold at 110% of rated current (1) and trip at 138% of rated current (2).
At 140°F, the same device will hold at approximately 92% of rated current (3), and trip at approximately 120% of rated current (4).