The Klixon M1 precision thermostat is constructed with a snap acting bimetal disc that
serves as the actuating element. As the temperature reaches a predetermined calibration
point the disc snaps to reverse its curvature, producing the crisp, positive switching
action inherent to Klixon thermostats. This feature assures reliable consistent
operating temperature over a longer cycle life.
The M1/11041 series of thermostats are engineered for exceptional vibration and shock resistance to
provide reliable switching in the most demanding applications. Prior to the final weld, finished assemblies are vacuum baked and back–filled with dry nitrogen. The inert, dry atmosphere eliminates moisture and other volatiles to prevent condensation at low temperatures or possible contact contamination at high temperatures. This back–fill also improves the dielectric characteristics of the device and prevents oxidation of the contacts. The M1 thermostat is the ideal choice where quality and reliability are paramount.
All M1 thermostats are supplied with single pole, single throw switching that can be constructed as either normally closed or normally open. The opening and closing temperatures are pre–set and non-adjustable.
For more information, see the page of free drawings
available for download.
PERFORMANCE Contact Ratings (resistive)
30 VAC/DC |
125 VAC |
250 VAC |
Life Cycles |
Amperes |
5.0 |
2.0 |
1.0 |
100,000 |
5.5 |
3.0 |
1.5 |
50,000 |
6.0 |
4.0 |
2.0 |
25,000 |
6.5 |
5.0 |
2.5 |
10,000 |
7.0 |
6.0 |
3.0 |
5,000 |
Based on standard differential
The standard M1 utilizes silver contacts. Gold plated contacts can be furnished to assure reliable
circuit switching under low wattage conditions per the following table.
30 VAC/DC |
500 mA and below |
115 VAC |
200 mA and below |
230 VAC |
100 mA and below |
Note: Other contact material may be appropriate for certain applications. Contact Sensata for
additional application support.
Contact Resistance |
0.050 ohms maximum per MIL-STD-202, Method 307 |
Dielectric Strength |
1250 VAC, rms, 60 cycles for 1 minute, terminal to case per MIL-STD-202, Method 301 |
Vibration Resistance |
5-2000 Hz, 20G, per MIL-STD-202, Method 204, Condition D (monitored) |
5-1000 Hz, 100G, per MIL-STD-202, Method 204, Condition D (unmonitored) |
1000-2000 Hz, 50G, per MIL-STD-202, Method 204, Condition D (unmonitored) |
Shock Resistance |
100G, 6 milliseconds, per MIL-STD-202, Method 213 |
Hermeticity |
1 X 10-8 atm cc/second maximum, per MIL-STD-202, Method 112, Condition C |
Salt Spray Resistance |
Per MIL-STD-202, Method 101, Condition B, 5% solution |
Moisture Resistance |
Per MIL-STD-202, Method 106 |
Weight (average) |
Basic Unit.
4.8 grams
w/ bracket
5.9 grams |
Ambient Temperature Range |
-80°F to +550°F, (-62.2°C to +287.8°C)
w/ bracket
5.9 grams |
Maximum ambient exposure while in the closed position is 200°F
above contact closing temperature.
Operating Temperature Range |
-65°F to 550°F, (-53.9°C to +287.8°C) |
Finish |
The standard plating is copper–nickel, but other finishes are available. |
Wire Leads |
Standard 18 gauge, stranded wire leads are available in white or black Teflon* insulation, in accordance with MIL-W-22759/11. Other wires are available upon request. |
*Trademark of E. I. Dupont de Namers and Co.
Operating Temperature |
Differential |
Tolerance |
°F |
°C |
°F |
°C |
±°F |
±°C |
-65 |
-53.9 |
30 |
16.7 |
10 |
5.6 |
-40 |
-40.0 |
30 |
16.7 |
10 |
5.6 |
-15 |
-26.1 |
30 |
16.7 |
10 |
5.6 |
0 |
-17.8 |
20 |
11.1 |
5 |
2.8 |
10 |
-12.2 |
20 |
11.1 |
5 |
2.8 |
20 |
-6.7 |
20 |
11.1 |
5 |
2.8 |
30 |
-1.1 |
20 |
11.1 |
5 |
2.8 |
40 |
4.4 |
20 |
11.1 |
5 |
2.8 |
Operat. Temp. |
Differential |
Tolerance |
°F |
°C |
°F |
°C |
±°F |
±°C |
50 |
10.0 |
20 |
11.1 |
5 |
2.8 |
60 |
15.6 |
20 |
11.1 |
5 |
2.8 |
70 |
21.1 |
20 |
11.1 |
5 |
2.8 |
80 |
26.7 |
20 |
11.1 |
5 |
2.8 |
90 |
32.2 |
20 |
11.1 |
5 |
2.8 |
100 |
37.8 |
20 |
11.1 |
5 |
2.8 |
110 |
43.3 |
20 |
11.1 |
5 |
2.8 |
120 |
48.9 |
20 |
11.1 |
5 |
2.8 |
Operat. Temp. |
Differential |
Tolerance |
°F |
°C |
°F |
°C |
±°F |
±°C |
130 |
54.4 |
20 |
11.1 |
5 |
2.8 |
140 |
60.0 |
20 |
11.1 |
5 |
2.8 |
150 |
65.6 |
20 |
11.1 |
5 |
2.8 |
160 |
71.1 |
20 |
11.1 |
5 |
2.8 |
170 |
76.7 |
20 |
11.1 |
5 |
2.8 |
180 |
82.2 |
20 |
11.1 |
5 |
2.8 |
190 |
87.8 |
20 |
11.1 |
5 |
2.8 |
200 |
93.3 |
20 |
11.1 |
5 |
2.8 |
Operat. Temp. |
Differential |
Tolerance |
°F |
°C |
°F |
°C |
±°F |
±°C |
210 |
98.9 |
30 |
16.7 |
8 |
4.4 |
220 |
104.4 |
30 |
16.7 |
8 |
4.4 |
230 |
110.0 |
30 |
16.7 |
8 |
4.4 |
240 |
115.6 |
30 |
16.7 |
8 |
4.4 |
250 |
121.1 |
30 |
16.7 |
8 |
4.4 |
260 |
126.7 |
30 |
16.7 |
8 |
4.4 |
270 |
132.2 |
30 |
16.7 |
8 |
4.4 |
280 |
137.8 |
30 |
16.7 |
8 |
4.4 |
Operat. Temp. |
Differential |
Tolerance |
°F |
°C |
°F |
°C |
±°F |
±°C |
290 |
143.3 |
30 |
16.7 |
8 |
4.4 |
300 |
148.9 |
30 |
16.7 |
8 |
4.4 |
310 |
154.4 |
40 |
22.2 |
12 |
6.7 |
320 |
160.0 |
40 |
22.2 |
12 |
6.7 |
330 |
165.6 |
40 |
22.2 |
12 |
6.7 |
340 |
171.1 |
40 |
22.2 |
12 |
6.7 |
350 |
176.7 |
40 |
22.2 |
12 |
6.7 |
375 |
190.6 |
40 |
22.2 |
12 |
6.7 |
Operat. Temp. |
Differential |
Tolerance |
°F |
°C |
°F |
°C |
±°F |
±°C |
400 |
204.4 |
40 |
22.2 |
12 |
6.7 |
425 |
218.3 |
40 |
22.2 |
12 |
6.7 |
475 |
246.1 |
70 |
38.9 |
25 |
13.9 |
450 |
232.2 |
40 |
22.2 |
12 |
6.7 |
525 |
273.9 |
70 |
38.9 |
25 |
13.9 |
500 |
260.0 |
70 |
38.9 |
25 |
13.9 |
550 |
287.8 |
70 |
38.9 |
25 |
13.9 |
Consult Sensata Technologies if desired operating temperature does not appear on table. |
CONFIGURATIONS
Standard configurations are available as the M1 series and are shown below. Many other configurations are available as the 11041 series.