Performance Characteristics |
/\ Top |
|
Rated Voltage |
125VAC / 250VAC |
Dimensions |
23.3 x 10.5 x 5.1 mm (including terminals) |
Current Range |
5–30 A (at 10 s trip–time) |
First On Times |
>3 seconds or >5 seconds (depending on bimetal type) |
On-winding Motor Protector |
A type: Standard
B type: Improved sealing (hotmelt) |
Cycle Life |
10.000 cycles / 13 A / 250 Vdc (see data sheet) |
Temperature Ranges |
Open Temperature: 65°C to 170°C in increments of 5°C |
Standard Operating Temperature: 65°C to 170°C |
Tolerance: ±5K |
Differential between open and close temperatures: 25K–45K (depends on open temperature) |
Maximum Ambient Temperature: 180°C |
Maximum Terminal Temperature: 185°C |
Continuous: Open temperature +20°C |
Overshoot: 5 minutes at 200°C |
Vibration |
Military standard 202E/204C, category D (20g peak) |
Corrosion |
14 days according to IEC 60730-1, §22 |
Thermal shock |
-40°C to +190°C, 10 cycles according to IEC 68-2-14, test Na |
Contact Rating Thermal Cut–out |
13(5)Amp 10.000 cycles
20(5)Amp 3.000 cycles (special rating to EN61558) |
Contact Rating Motor Protector |
Rating depends on the application and its test results |
Declarations to EN60730-2-9 |
/\ Top |
|
Purpose of the control |
Thermal cut–out |
Construction |
Incorporated, non–electronic |
Degree of protection |
IP00 |
Terminals for external conductors |
For internal conductors only |
Temperature limits of the switchhead |
180°C |
PTI of insulation materials |
PTI 175 |
Method of mounting |
Inserting, clamping, bracketing or the like |
Operating time |
For continuous operation |
Types of action |
Type 2C (T - open) Type 1C (T - close) |
Reset characteristic |
Automatic |
Extent of sensing element |
Whole control |
Control pollution degree |
Degree 2 |